Automatic True Position Measurement of a Cylindrical Feature

True Position measurement of a cylindrical feature inspected using Polar basic dimensions

In this example, the hole’s nominal center point is defined precisely at 60 degrees clockwise on a radius of .750 inches centered about the part’s center hole. The actual center of the hole is located, and the software automatically computes the True Position of the feature and reports a Pass/Fail result based on the diametric tolerance zone defined.